1. 首页
  2. 移动开发
  3. 其他
  4. 艾默生CT励磁控制器 FXMP25.pdf

艾默生CT励磁控制器 FXMP25.pdf

上传者: 2020-07-29 21:46:41上传 PDF文件 2.35MB 热度 85次
艾默生CT励磁控制器 FXMP25pdf,艾默生CT励磁控制器 FXMP25ContentsSafety information………,…,…,…,…,"…,…,…,……6Warnings cautions and notes61.2Electrical safety-general warning1.3System design and safety of personnel6Environmental limitsAFire proteCompliance with regulationMotor1.9Adjusting parameters1.10Electrical installationProduct information2.1Ratings92.2Nameplate description92.3FXMP25 features and optionsMechanical installlation11Electrical terminalsRoutine maintenance13Electrical installation14Electrical connections154.2Protective earth connectionsAC supply requirements164.4Line reactors164.5Cable and fuse size ratingsGetting started∴24Keypad and displa245.2Resetting the field controllerSecurity2554Setting the controller back to default values65.5Saving parametersParameters…n,276.1Full parameter descriptions28FXMP25 User GuideIssue Number: 2www.controltechniques.comSetting-up ...a.Technical data488.1Ratings8.2FXMP25 derating for extended ambient operation8.3Power dissipation14884Ac supply requirements498.58.6Temperature and humidity498.7Storage.508.8Altitud8.9IP rati8.10Corrosive gasses518.11RoHS compliance518.12Vibration518.13Acoustic nois8.14Overall dimension528.15Weight………8.16Cable and fuse size ratings8.17Electromagnetic compatibility(EMC)Diagnostics5510UL listing information………5910.1Conditions of acceptability10.2AC supply specification10.3Maximum continuous current59FXMP25 User Guidwww.controltechniques.comIssue number: 2Declaration of ConformityControl Techniques Ltd, The Gro, Newtown, Powys UK. sY16 3BEFXMP25 Field ControllerThe field controller product listed above has been designed and manufactured inaccordance with the following European harmonized standardsEN61800-5-1:2007Adjustable speed electrical power drive systems-safetyrequirements-electrical, thermal and energyEN61800-3:2004Adjustable speed electrical power drive systems. EMCproduct standard including specific test methodsElectromagnetic compatibility(EMC). Generic standardsEN 61000-6-2: 2005 Immunity standard for industrial environmentsEN 61000 6-4: 2007/Electromagnetic compatibility(EMC).Generic standardEmission standard for industrial environmentsThe corresponding international standards areEC61800-5-1:2007EC61800-3:2004EC61000-6-2:2005EC61000-6-4:2006These products comply with the Low Voltage Directive 2006/95/EC and theElectromagnetic Compatibility(EMC)Directive 2004/108/ECT AlexanderVP TechnologyNewtownDate: 8th July 2010This electronic field controller product is intended to be used with appropriatemotors, controllers, electrical protection components and other equipment toform complete end products or systems. Compliance with safety and EMcregulations depends upon installing and configuring drives correctly, includingusing the specified input filters. The drives must be installed only by professionalassemblers who are familiar with re quirements for safety and EMc. theassembler is responsible for ensuring that the end product or system complieswith all the relevant laws in the country where it is to be used. Refer to the UserGuide. An EMC Data Sheet is also available giving detailed EMC informationFXMP25 User GuideIssue number: 2www.controltechniques.comSafety informationWarnings, cautions and notes△A Warning contains information, which is essential for avoiding a safety hazardWARNINA Caution contains information, which is necessary for avoiding a risk of damage tothe product or other equipmentCAUTNOTE A Note contains information which helps to ensure correct operation of the product1.2 Electrical safety- general warningThe voltages used in the field controller can cause severe electrical shock and/or burnsand could be lethal. Extreme care is necessary at all times when working with oradjacent to the field controller.Specific warnings are given at the relevant places in this Guide1.3 System design and safety of personnelThe field controller is intended as a component for professional incorporation intocomplete equipment or system. If installed incorrectly, the field controller may present asatety hazardThe field controller uses high voltages and currents, carries a high level of storedelectrical energy, and is used to control equipment which can cause injurySystem design, installation, commissioning /start-up and maintenance must be carriedout by personnel who have the necessary training and experience. They must read thissafety information and this guide carefullyThe electrical inputs of the field controller must not be relied upon to ensuresafety of personnel. they do not isolate dangerous voltages from the output ofthe field controller. The supply must be disconnected by an approved electricalisolation device before gaining access to the electrical connectionsThe field controller is not intended to be used for safety-related functionsCareful consideration must be given to the function of the field controller which mightresult in a hazard, either through its intended behavior or through incorrect operationdue to a fault. In any application where a malfunction of the field controller or its controlsystem could lead to or allow damage, loss or injury, a risk analysis must be carried out,and where necessary, further measures taken to reduce the risk-for example, an overspeed protection device in case of failure of the field controlFXMP25 User Guidewww.controltechniques.comIssue number 2Environmental limitsInstructions within the supplied data regarding transport, storage, installation and theuse of the field controller must be complied with, including the specified environmentallimits. Field controllers must not be subjected to excessive physical force3391.5AccessAccess must be restricted to authorized personnel only. Safety regulations which applyat the place of use must be complied with1.6 Fire protectionThe field controller enclosure is not classified as a fire enclosure. a separate fireenclosure must be providedd7 Compliance with regulationsThe installer is responsible for complying with all relevant regulations, such as nationalwiring regulations, accident prevention regulations and electromagnetic compatibility(EMC)regulations. Particular attention must be given to the cross-sectional areas ofmconductors, the selection of fuses and other protection, and protective earthconnectionsThe FXMP25 User Guide contains instructions for achieving compliance with specificEMC standardsithin the European Union, all machinery in which this product is used must complywith the following directia2006/42/EC: Safety of machinery2004/108/EC: Electromagnetic compatibility18MeotorEnsure the motor is installed in accordance with the manufacturers recommendationsU03Ensure the motor shaft is not exposedLow speeds may cause the motor to overheat because the cooling fan becomes lesseffective. The motor should be installed with a protection thermistor. If necessary, anelectric forced ventilation fan should be usedThe values of the motor parameters set in the field controller affect the protection of themotor The default values in the field controller should not be relied upon1.9 Adjusting parametersSome parameters have a profound effect on the operation of the field controller. Theymust not be altered without careful consideration of the impact on the controlled systemMeasures must be taken to prevent unwanted changes due to error or tamperingFXMP25 User Guide7Issue Number: 2www.controltechniques.com1.10 Electrical installation1.10.1 Electric shock riskThe voltages present in the following locations can cause severe electric shock and maybe lethalAC supply cables and connectionsOutput cables and connectionsMany internal parts of the field controllerUnless otherwise indicated, control terminals are single insulated and must not betouched1.10.2 Stored chargeThe field controller contains capacitors that remain charged to a potentially lethalvoltage after the AC supply has been disconnected. If the field controller has beenenergized, the ac supply must be isolated at least five minutes before work maycontinueFXMP25 User Guidewww.controltechniques.comIssue number: 22Product information2.1RatingsMaximum continuous input currentThe value of the maximum continuous input current is given to aid the selection ofcables and fuses the value is stated for worst-case conditionsContinuous AcContinuous dcinput currentoutput current500=卫2.2Nameplate descriptionFigure 2-1 Typical FXMP25 rating labelFX.External FieldMP.Mentor platform25Maximum field current (A)Customer anddate codeLine input voltageFXMP26 Field ControllerSTDN39frequency/currentInput 208-480V 50-60Hz 1 ph 26AOutput±430V=25AField outputvoltage/ currentmm、Nsc《e+Aas量Serial numberKey to approvals〔∈ ce approvaEuropeRoHS RoHS compliantEuropeCompliantCTusUL approvalWorldwidec cTick approvaustralia2.2.1 Output currentThe continuous output current ratings given on the rating label are for maximum 40C(104 F)and 1000m altitude Derating is required for higher ambient temperatures40C(104F)and higher altitude For derating information, refer to Chapt8 Technical data on page 482.2.2 Input currentThe input current given on the rating label is the typical input currentFXMP25 User GuideIssue Number: 2www.controltechniques.com2.3 FXMP25 features and optionsFigure 2-2 FXMP25 features下世世世世哥會世世會FXMP25BB-B.BBBDisplayAMentor MP/serial port connectorGroundMentor ll Control Armature voltageconnectionand field outputconnectionsconnector terminalsfeedbackconnections2.3.1 Options available for FXMP25Table 2-1 OptionsTypeCableNameFurther detailsFXMP25 User Guidewww.controltechniques.comIssue number: 2
下载地址
用户评论